{"product_id":"infwin-digiphorp","title":"INFWIN DigiPHORP Digital PH and ORP Sensor","description":"\u003cp\u003eThe INFWIN DigiPHORP is a digital pH and ORP (oxidation-reduction potential) sensor with SDI-12 or RS485\/Modbus-RTU output, integrating both electrodes and the transmission circuit into a single compact IP68-rated probe. Output interface and cable length are configurable via ordering code - the default variant (DigiPHORP-AACC002) ships with an ABS+PC shell, a combined pH and ORP electrode with built-in temperature compensation, RS485\/Modbus-RTU output, 4.5–28V DC supply, and a 2 m cable.\u003c\/p\u003e\n\u003cp\u003eA 3\/4\" NPT thread makes the sensor easy to mount for submersible installation or fit directly into pipelines and tanks. Reverse power protection and built-in TVS\/ESD protection are included.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual measurement:\u003c\/strong\u003e pH and ORP from a single combined electrode and transmitter circuit, in one compact IP68-rated body\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in temperature compensation:\u003c\/strong\u003e Electrode includes a temperature sensor to compensate both pH and ORP readings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh precision and good interchangeability:\u003c\/strong\u003e Consistent readings across sensor units\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDigital output:\u003c\/strong\u003e SDI-12 (V1.3) for universal datalogger compatibility and low-power use, or RS485\/Modbus-RTU for long cable runs or multi-sensor networks, both with surge protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4\" NPT threading:\u003c\/strong\u003e Convenient for submersible installation or mounting in pipelines and tanks\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow power consumption:\u003c\/strong\u003e Suited to battery-powered systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse power protection:\u003c\/strong\u003e Built-in TVS\/ESD protection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration utility:\u003c\/strong\u003e SensorOneSet software (RS485) or SensorOneSetSDI12 software (SDI-12) included for sensor configuration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eODM\/OEM service available\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable length:\u003c\/strong\u003e 2 m standard; custom lengths available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial process monitoring\u003c\/li\u003e\n\u003cli\u003eWater and wastewater treatment\u003c\/li\u003e\n\u003cli\u003eSewerage systems\u003c\/li\u003e\n\u003cli\u003eIrrigation and smart agriculture\u003c\/li\u003e\n\u003cli\u003eAquaculture and hydroponics\u003c\/li\u003e\n\u003cli\u003eLoRaWAN IoT deployments via the Catena-5310 or compatible RS485\/Modbus-RTU\/SDI-12 gateway\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eImportant Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature for the sensor body is 0°C to +80°C, narrower than the electrode's own −40°C to +80°C measurement range.\u003c\/li\u003e\n\u003cli\u003eRated for operating humidity 0–100% and pressure up to 0.2 MPa; storage conditions are −5°C to +65°C, 0–90% humidity.\u003c\/li\u003e\n\u003cli\u003eThe combined electrode is a wear item; periodic calibration and eventual electrode replacement should be expected as part of normal maintenance.\u003c\/li\u003e\n\u003cli\u003epH response time (under 10 s) is faster than ORP response time (under 30 s) - allow the longer settling time before logging ORP readings.\u003c\/li\u003e\n\u003cli\u003eUnlike the single-parameter DigiPH and DigiORP, this sensor's RS485 quiescent current is slightly higher (\u0026lt;8 mA vs \u0026lt;5 mA) due to the combined electrode circuitry.\u003c\/li\u003e\n\u003cli\u003eWhen using Active Output mode on RS485, only one sensor should be on the network to avoid data collision.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e0–14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e\u0026lt;10 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eORP (Oxidation-Reduction Potential)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e−2000.0 to +2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e±20 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eResponse time\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e\u0026lt;30 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTemperature (compensation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eRange\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e−40°C to +80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eElectrical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eOutput interface\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003eRS485 (Modbus-RTU) or SDI-12, V1.3 (selectable via ordering code)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003ePower supply\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e4.5–28V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eQuiescent current\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003eSDI-12: \u0026lt;10 µA @ 12V DC; RS485: \u0026lt;8 mA @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eMeasuring current\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e\u0026lt;10 mA @ 12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eMechanical\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e207 × 30 mm (length × diameter), 3\/4\" NPT threading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eShell material\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003eABS + PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eIP rating\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003eIP68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eCable length\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e2 m standard; custom length available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eEnvironmental\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eOperating conditions\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e0°C to +80°C; 0–100% humidity; pressure ≤0.2 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 26.6455%;\"\u003eStorage conditions\u003c\/td\u003e\n\u003ctd style=\"width: 68.7527%;\"\u003e−5°C to +65°C; 0–90% humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 1: Product Series\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDigiPHORP\u003c\/td\u003e\n\u003ctd\u003eDigiPHORP Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 2: Shell Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003eABS + PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 3: Electrode Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eA\u003c\/td\u003e\n\u003ctd\u003epH and ORP Electrode (built-in temperature compensation sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 4: Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003c\/td\u003e\n\u003ctd\u003e4.5–28V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 5: Output Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC\u003cbr\u003eF\u003c\/td\u003e\n\u003ctd\u003eRS485, Modbus-RTU\u003cbr\u003eSDI-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCode 6: Cable Length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e002\u003cbr\u003eXXX\u003c\/td\u003e\n\u003ctd\u003e2 meters\u003cbr\u003eCustom (XXX = length in meters, e.g. 005 = 5 m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eDefault Variant: DigiPHORP-AACC002\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShell material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS + PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003epH and ORP electrode with built-in temperature compensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.5–28V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutput interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRS485, Modbus-RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable length\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 meters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eCustom variants (output interface, cable length) are available - \u003ca href=\"https:\/\/mcci.com\/contact\/\" rel=\"noopener\" target=\"_blank\"\u003econtact us\u003c\/a\u003e to discuss your requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Documents\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infwin.com\/wp-content\/uploads\/DigiPHORP-Digital-PH-and-ORP-Sensor-User-Manual-RS485-SDI-12-Interface.pdf\" title=\"DigiPHORP User Manual\" rel=\"noopener\" target=\"_blank\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infwin.com\/wp-content\/uploads\/SensorOneSet-EN.zip\" title=\"SensorOneSet Configuration Utility (RS485)\" rel=\"noopener\" target=\"_blank\"\u003eSensorOneSet Configuration Utility (RS485)\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/www.infwin.com\/wp-content\/uploads\/SensorOneSetSDI12-EN.zip\" title=\"SensorOneSetSDI12 Configuration Utility (SDI-12)\" rel=\"noopener\" target=\"_blank\"\u003eSensorOneSetSDI12 Configuration Utility (SDI-12)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eModbus is a registered trademark of Schneider Electric. SDI-12 is a trademark of the SDI-12 Support Group. INFWIN is a registered trademark of Dalian Endeavour Technology Co., Ltd. MCCI and MCCI Catena are registered trademarks of MCCI Corporation. All other trademarks are the property of their respective owners.\u003c\/h5\u003e","brand":"INFWIN","offers":[{"title":"DigiPHORP-AACC002","offer_id":54153030369598,"sku":"123004236","price":259.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0873\/5104\/files\/DigiPHORP.png?v=1787222613","url":"https:\/\/store.mcci.com\/products\/infwin-digiphorp","provider":"MCCI","version":"1.0","type":"link"}